For many environments, a Qlogic switch can be as simple as plugging it into the wall to get working. The web interface is a great tool and appropriate for many a configuration, but the interactive shell environment on the switches gives a few more options. Let’s first get logged into the switch. The switch will have an IP address, so telnet into that address (I’ll use the my IP rather than the default IP of 10.0.0.1 that the switches ship with):
telnet 192.168.210.87
Once you provide a password you’ll be placed into an Interactive Command Line Interface SHell environment, which Qlogic calls CLISH.
Establishing connection…   Please wait. ***************************************************** *                                                   * *       Command Line Interface SHell  (CLISH)       * *                                                   * ***************************************************** SystemDescription   SANbox 5600 FC Switch HostName            5600 EthIPv4NetworkAddr  192.168.210.87 EthIPv6NetworkAddr  ab50::2c0:eeaa:fe17:337e MACAddress          00:c0:dd:07:37:7e WorldWideName       10:00:00:c0:bd:07:27:74 SerialNumber        0240A00557 SymbolicName        CHARLES_HOME_TEST_5600 ActiveSWVersion     V7.4.0.16.0 ActiveTimestamp     Thu Mar 19 22:20:51 2009 DiagnosticsStatus   Passed LicensedPorts       20 SwitchMode          Full Fabric
This switch supports a dual-stacked IPv4 and IPv6 network connection. Use the ‘set setup system’ command to change the network settings. Either IPv4 or IPv6 can be disabled, otherwise the switch will run in dual-stack mode.
Because you need to be an administrator to do almost anything fun on these things, let’s start an administrative session by issuing the admin command in the interactive shell, followed by the start verb:
admin start
Next up, let’s look at our active ports using the show command, along with the port verb:
show port
Once we can see our ports, let’s check out one specific port, again using the show port, but this time specifying a port number:
show port 2
Which results in:
Port Number: 2 ———— AdminState       Online              OperationalState Offline AsicNumber       0                   PerfTuningMode   Normal AsicPort         2                   PortID           030200 ConfigType       F                   PortWWN          20:02:00:d0:bb:07:34:75 DiagStatus       Passed              RunningType      Unknown DownstreamISL    False               MediaPartNumber  AFBR-57D7APZ EpConnState      None                MediaRevision    G2.3 EpIsoReason      NotApplicable       MediaType        800-MX-SN-I IOStreamGuard    Enabled             MediaVendor      AVAGO Licensed         True                MediaVendorID    0000176a LinkSpeed        4Gb/s               SupportedSpeeds  1, 2, 4Gb/s LinkState        Inactive            SymbolicName     Port2 LoginStatus      NotLoggedIn         SyncStatus       SyncLost MaxCredit        16                  UpstreamISL      False MediaSpeeds      2, 4, 8Gb/s         XmitterEnabled   True ALInit             0                   LIP_F8_F7          0 ALInitError        0                   LinkFailures       0 BadFrames          0                   Login              0 BBCR_FrameFailures 0                   Logout             0 BBCR_RRDYFailures  0                   LongFramesIn       0 Class2FramesIn     0                   LoopTimeouts       0 Class2FramesOut    0                   LossOfSync         0 Class2WordsIn      0                   LostFrames         0 Class2WordsOut     0                   LostRRDYs          0 Class3FramesIn     0                   PrimSeqErrors      0 Class3FramesOut    0                   RxLinkResets       0 Class3Toss         0                   RxOfflineSeq       0 Class3WordsIn      0                   ShortFramesIn      0 Class3WordsOut     0                   TotalErrors        0 DecodeErrors       0                   TotalLinkResets    0 EpConnects         0                   TotalLIPsRecvd     0 FBusy              0                   TotalLIPsXmitd     0 FlowErrors         0                   TotalOfflineSeq    0 FReject            0                   TotalRxFrames      0 InvalidCRC         0                   TotalRxWords       0 InvalidDestAddr    0                   TotalTxFrames      0 LIP_AL_PD_AL_PS    0                   TotalTxWords       0 LIP_F7_AL_PS       0                   TxLinkResets       0 LIP_F7_F7          0                   TxOfflineSeq       0
This shows us a pretty good amount of information, from the link speed plugged into a given port to the brand of transceiver that is being used and the WWN of the actual , in this case, initiator. We also see whether or not IOStreamGuard is enabled (in this case we’re dealing with an initiator, so it is) and what the available media speeds are for the port as well as available speeds for that port. Also notice that the ports have no statistics. Here, we want to keep an eye on things like TotalErrors, LIPs (LIP*), LinkFailures, RxLinkResets and ALInitError. Basically, if it’s in the above list and it sounds bad then it probably is… Because switches have been running in many cases for years, it turns out that sometimes you’ll find resetting port statistics to be pretty helpful as it will enable you to see only the latest information for troubleshooting. When troubleshooting, you can use the baseline options in the GUI, but every now and then while you’re troubleshooting, many will want to work with as small a subset of data as possible and so will want to clear out information regarding a port. The GUI can clear baseline stats, but not historical statistics. To clear these stats, we’re going to use the set command, along with the port (as we’re setting something on a port) followed by the clear verb and then the port number:
set port clear 1
You can also do the same command without indicating a port numbering order to clear ’em all out:
set port clear
Show also comes with a an option to show logs:
show log
And to see more historical information:
show log archive
I usually pipe that information into a text file for easier parsing. Because the date seems off on most switches where people forget to put time servers in, running the date command will let you figure out an appropriate offset for log file isolation:
date
And one of my favorite commands tells me how long the switch has been up:
uptime
As with Mac OS X and linux, the ps command shows us running processes:
ps
And show interface is the equivalent of an ifconfig in a standard shell environment:
show interface
And many a problem is based on a port configuration issue, so to see information on a given port:
show config port 2
Which results in:
—- Configuration Name: default ——————- Port Number: 2 ———— AdminState           Online LinkSpeed            Auto PortType             F SymbolicName         Port2 ALFairness           False DeviceScanEnabled    True ForceOfflineRSCN     False ARB_FF               False InteropCredit        0 ExtCredit            0 FANEnabled           True AutoPerfTuning       True MSEnabled            True NoClose              False IOStreamGuard        Disabled PDISCPingEnabled     True
Next up, let’s look at zoning. This is one of the most common things that you’ll need to use the command line for as you cannot enable the default zone using the GUI and the 9200 ships with it disabled. To start off, let’s use that show command, along with the config (as we’re going to be looking at a configuration option) and then zoning so we only see our options for zoning:
show config zoning
While we’re in admin mode, we’re not a mode to edit our configuration, so let’s jump into the config mode:
config edit
Now that we can actually edit our configuration, let’s run the set command, along with the config and then zoning:
set config zoning
On a 56xx, this brings up a little wizard that asks us 3 questions, the current answer to which is in brackets and can be retained by simply hitting the enter key for that option. Or, type the other option. In the following example we’re allowing the DefaultZone:
MergeAutoSave         (True / False)  [True ] DefaultZone           (Allow / Deny)  [Deny ]  Allow DiscardInactive       (True / False)  [False]
But on a 9×00 it brings up 4 options, the 4th being oft problematic as most Xsan’s these days seem to have more than 64 nodes per zone (although most Xsan environments are’t gonna’ hit the 10,000 limit):
Zoning Configuration Information ——————————– MergeAutoSave         True DefaultZone           Allow DiscardInactive       False ImplicitHZ            False
And then we’re saving our configuration to nvram:
config save
Now that you have a new configuration saved,  you can activate it to be live (be careful not to knock ports offline if you are in a production environment):
config activate
To then look at the zone sets configured on the device (or fabric):
zoneset list
And to see which is active:
zoneset active
And to see what this means (ie a list of wwnns per zone:
zoning active
The admin command has an option to use an end verb, which intriguingly ends an active administrative session:
admin end
Since we’re done, we’ll issue a quit command:
quit
Let’s log into a 9200 and look at one more thing before I wrap this little article:
login: admin Password: Establishing connection…   Please wait. ***************************************************** *                                                   * *       Command Line Interface SHell  (CLISH)       * *                                                   * ***************************************************** SystemDescription   SANbox 9000 Series HostName            Qlogic9200 EthIPv4NetworkAddr  192.168.210.88 EthIPv6NetworkAddr  <undefined> MACAddress          00:c0:dd:0c:12:ce WorldWideName       10:00:00:c0:ee:1d:72:db ChassisSerialNumber 0816B50816 SymbolicName        Charles_Home_9200 ActiveSWVersion     V7.8.0.8.0 ActiveTimestamp     Fri Dec 26 17:50:21 2008 POSTStatus          Passed PrimaryCPU          CPU0 SecondaryCPUStatus  HotStandby (switch is Fault Tolerant)
And that last thing is to look at the environmental statistics on the 9200. To do so we’re going to continue on with that show command:
show env
Which gives us:
Temperature(C) Sensors: Blade ID  Sensor  Description  Status  Current  High Warn  High Alarm ——–  ——  ———–  ——  ——-  ———  ———- IO0            0  BOARD        Normal       41         75          85 IO0            1  DS1780_0     Normal       42         65          70 IO0            2  DS1780_1     Normal       41         65          70 IO0            3  MAX1617      Normal       42         65          70 IO0            4  ASIC         Normal       51         95         100 IO1            0  BOARD        Normal       43         75          85 IO1            1  DS1780_0     Normal       42         65          70 IO1            2  DS1780_1     Normal       41         65          70 IO1            3  MAX1617      Normal       42         65          70 IO1            4  ASIC         Normal       51         95         100 IO2            0  BOARD        Normal       41         75          85 IO2            1  DS1780_0     Normal       41         65          70 IO2            2  DS1780_1     Normal       40         65          70 IO2            3  MAX1617      Normal       41         65          70 IO2            4  ASIC         Normal       50         95         100 IO3            0  BOARD        Normal       40         75          85 IO3            1  DS1780_0     Normal       40         65          70 IO3            2  DS1780_1     Normal       39         65          70 IO3            3  MAX1617      Normal       40         65          70 IO3            4  ASIC         Normal       48         95         100 IO4            0  BOARD_0      Normal       38         75          85 IO4            1  BOARD_1      Normal       38         75          85 IO4            2  DS1780_0     Normal       39         65          70 IO4            3  DS1780_1     Normal       37         65          70 IO4            4  MAX1617      Normal       41         75          90 IO4            5  ASIC         Normal       73        110         120 IO6            0  BOARD        Normal       43         75          85 IO6            1  DS1780_0     Normal       42         65          70 IO6            2  DS1780_1     Normal       42         65          70 IO6            3  MAX1617      Normal       42         65          70 IO6            4  ASIC         Normal       52         95         100 IO7            0  BOARD        Normal       41         75          85 IO7            1  DS1780_0     Normal       41         65          70 IO7            2  DS1780_1     Normal       41         65          70 IO7            3  MAX1617      Normal       41         65          70 IO7            4  ASIC         Normal       49         95         100 CPU0           0  BOARD        Normal       41         75          85 CPU0           1  DS1780_0     Normal       40         65          70 CPU0           2  DS1780_1     Normal       40         65          70 CPU0           3  MAX1617_0    Normal       42         75          90 CPU0           4  ASIC_0       Normal       60        110         120 CPU0           5  MAX1617_1    Normal       42         75          90 CPU0           6  ASIC_1       Normal       54        110         120 CPU1           0  BOARD        Normal       41         75          85 CPU1           1  DS1780_0     Normal       41         65          70 CPU1           2  DS1780_1     Normal       41         65          70 CPU1           3  MAX1617_0    Normal       43         75          90 CPU1           4  ASIC_0       Normal       57        110         120 CPU1           5  MAX1617_1    Normal       42         75          90 CPU1           6  ASIC_1       Normal       53        110         120 Voltage Sensors: Blade ID  Sensor  Description  Status  Current  Low Alarm  High Alarm ——–  ——  ———–  ——  ——-  ———  ———- IO0            0  1.5V         Good       1.50       1.31        1.68 IO0            1  1.25V        Good       1.24       1.00        1.50 IO0            2  2.5V         Good       2.49       2.20        2.82 IO0            3  3.3V         Good       3.31       2.99        3.62 IO0            4  12V          Good      11.69      10.00       13.31 IO0            5  1.2V         Good       1.19       1.04        1.38 IO0            6  1.8V         Good       1.80       1.61        1.99 IO0            7  1.8V_ANALOG  Good       1.78       1.61        1.99 IO0            8  2.5V_ANALOG  Good       2.37       2.10        2.82 IO1            0  1.5V         Good       1.50       1.31        1.68 IO1            1  1.25V        Good       1.24       1.00        1.50 IO1            2  2.5V         Good       2.49       2.20        2.82 IO1            3  3.3V         Good       3.31       2.99        3.62 IO1            4  12V          Good      11.69      10.00       13.31 IO1            5  1.2V         Good       1.19       1.04        1.38 IO1            6  1.8V         Good       1.80       1.61        1.99 IO1            7  1.8V_ANALOG  Good       1.78       1.61        1.99 IO1            8  2.5V_ANALOG  Good       2.39       2.10        2.82 IO2            0  1.5V         Good       1.50       1.31        1.68 IO2            1  1.25V        Good       1.24       1.00        1.50 IO2            2  2.5V         Good       2.51       2.20        2.82 IO2            3  3.3V         Good       3.31       2.99        3.62 IO2            4  12V          Good      11.69      10.00       13.31 IO2            5  1.2V         Good       1.19       1.04        1.38 IO2            6  1.8V         Good       1.80       1.61        1.99 IO2            7  1.8V_ANALOG  Good       1.78       1.61        1.99 IO2            8  2.5V_ANALOG  Good       2.37       2.10        2.82 IO3            0  1.5V         Good       1.50       1.31        1.68 IO3            1  1.25V        Good       1.24       1.00        1.50 IO3            2  2.5V         Good       2.49       2.20        2.82 IO3            3  3.3V         Good       3.31       2.99        3.62 IO3            4  12V          Good      11.75      10.00       13.31 IO3            5  1.2V         Good       1.19       1.04        1.38 IO3            6  1.8V         Good       1.80       1.61        1.99 IO3            7  1.8V_ANALOG  Good       1.78       1.61        1.99 IO3            8  2.5V_ANALOG  Good       2.39       2.10        2.82 IO4            0  2.5V         Good       2.50       2.20        2.80 IO4            1  1.25V        Good       1.24       1.00        1.50 IO4            2  3.3V         Good       3.32       3.02        3.58 IO4            3  5V           Good       4.92       4.37        5.55 IO4            4  12V          Good      11.75      10.00       13.31 IO4            5  1.5V         Good       1.48       1.31        1.68 IO4            6  1.8V         Good       1.78       1.61        1.99 IO6            0  1.5V         Good       1.50       1.31        1.68 IO6            1  1.25V        Good       1.24       1.00        1.50 IO6            2  2.5V         Good       2.49       2.20        2.82 IO6            3  3.3V         Good       3.31       2.99        3.62 IO6            4  12V          Good      11.69      10.00       13.31 IO6            5  1.2V         Good       1.19       1.04        1.38 IO6            6  1.8V         Good       1.80       1.61        1.99 IO6            7  1.8V_ANALOG  Good       1.76       1.61        1.99 IO6            8  2.5V_ANALOG  Good       2.39       2.10        2.82 IO7            0  1.5V         Good       1.48       1.31        1.68 IO7            1  1.25V        Good       1.24       1.00        1.50 IO7            2  2.5V         Good       2.48       2.20        2.82 IO7            3  3.3V         Good       3.31       2.99        3.62 IO7            4  12V          Good      11.69      10.00       13.31 IO7            5  1.2V         Good       1.20       1.04        1.38 IO7            6  1.8V         Good       1.80       1.61        1.99 IO7            7  1.8V_ANALOG  Good       1.78       1.61        1.99 IO7            8  2.5V_ANALOG  Good       2.37       2.10        2.82 CPU0           0  1.55V        Good       1.54       1.42        1.68 CPU0           1  1.25V        Good       1.24       1.00        1.50 CPU0           2  1.8V         Good       1.79       1.60        1.99 CPU0           3  3.3V         Good       3.31       2.99        3.62 CPU0           4  12V          Good      11.69      10.00       13.31 CPU0           5  ASIC_0_1.5V  Good       1.47       1.31        1.68 CPU0           6  2.5V         Good       2.50       2.20        2.80 CPU0           7  ASIC_1_1.5V  Good       1.45       1.31        1.68 CPU0           8  3.3V         Good       3.30       3.02        3.58 CPU1           0  1.55V        Good       1.54       1.42        1.68 CPU1           1  1.25V        Good       1.24       1.00        1.50 CPU1           2  1.8V         Good       1.77       1.60        1.99 CPU1           3  3.3V         Good       3.31       2.99        3.62 CPU1           4  12V          Good      11.69      10.00       13.31 CPU1           5  ASIC_0_1.5V  Good       1.45       1.31        1.68 CPU1           6  2.5V         Good       2.49       2.20        2.80 CPU1           7  ASIC_1_1.5V  Good       1.45       1.31        1.68 CPU1           8  3.3V         Good       3.30       3.02        3.5
The reason I wanted to look at using the show env command with the 9200 is that it is one of the few that is supported in the 9200 and not in the 5600 series switches. Also, I thought it worth mentioning that given that the environmental options  are much different between the 9200 and 5600, Lithium, a popular tool for monitoring Xsan environments will show errors that the 9200 has problems in the event you add it to a Lithium Console (which makes my iPad go batty with vibrations). To see the information on the snmp configuration, you guessed it: